Water Filters vs Water Softeners: What Each One Does
Water filters and water softeners solve different problems. See what each removes, what a softener needs to keep running and the rules for installing either.
Part of our series. Start with the main guide for the basics:Water Softeners Buying Guide: What to Check Before You Buy
A softener and a filter do different jobs, so you are not really choosing between two versions of the same thing. A softener targets hardness, the calcium and magnesium in water. A carbon filter is aimed at taste and odour compounds, and at contaminants such as nitrates, pesticides and disinfection by-products.[1],[2]
Pick a softener if scale and hard water are your problem. Pick carbon filtration if taste and odour compounds, nitrates or disinfection by-products are your concern. If you have both problems, you are dealing with two separate jobs.[1],[2]
Shared basics on choosing and sizing a softener are in our main guide at Water Softeners Buying Guide: What to Check Before You Buy
Key differences
**What each one targets:** The table sets out what a softener and a granular activated carbon filter are each used for. Softening exchanges hardness ions, while activated carbon removes contaminants through adsorption and biological degradation.[1],[2]
| Question | Water softener | Granular activated carbon filter |
|---|---|---|
| What does it target? | Hardness ions: calcium and magnesium[1] | Taste and odour compounds, nitrates, pesticides, algal toxins, disinfection by-products, organic carbon and other trace organic chemicals[2] |
| How does it work? | Ion exchange: hardness ions are swapped for non-hardness ions, typically sodium[1] | Adsorption, where contaminants stick to the carbon, plus biological degradation[2] |
NSF/ANSI 44 is a standard whose scope includes reducing hardness and specific contaminants from a water source of known quality. Compare what a particular unit says it is designed to reduce before you buy.[3]
**Taste and odour:** Activated carbon is used in water treatment to control taste and odour-causing compounds.[2]
Chlorine can be present in different forms. Free chlorine reacts with ammonia to form chloramines, and total chlorine is the free chlorine plus the combined chlorine. If a test report shows total chlorine, it includes both.[4]
**Nitrates and similar contaminants:** Activated carbon is listed among the treatment uses that remove contaminants such as nitrates, pesticides, algal toxins, disinfection by-products and organic carbon. Contaminants are removed through adsorption and biological degradation.[2]
Activated carbon used before disinfection reduces how many disinfection by-products form. It does this by cutting the amount and reactivity of the organic material they form from. This is a benefit specific to carbon treatment.[2]
**Hardness guideline:** The Australian Drinking Water Guidelines say total hardness (as calcium carbonate) in drinking water should not exceed 200 mg/L.[5]
**Softened water:** The same guidelines note some indication that soft water, with a hardness of less than about 75 mg/L, may adversely affect mineral balance. You may not want to soften all the way down.[5]
**Sodium:** Softening adds sodium to the water, at about 8 mg/L for each grain per gallon of hardness. Domestic water softeners can contribute to the sodium content of drinking water.[1],[6]
Sodium intake via the water supply makes only a modest contribution to total intake. Our home softener guide covers this in full at Water Softeners for the Home: How to Choose in Australia[6]
**Running needs:** A softener regenerates, meaning it recharges its resin with salt brine. The brine is pumped through the resin tank, then flushed to a drain with the hard minerals.[7]
- One regeneration uses roughly 50 gallons of water, which the source compares to a load of laundry in an older washing machine.[1]
- A regeneration takes about 20 to 35 minutes.[8]
- The salt used varies with household size, daily water use, softener capacity and water hardness. One reference gives 0.25 to 0.45 pounds of salt for every 1,000 grains of hardness removed.[1],[8]
- How often it regenerates depends on water hardness, the amount of water used, the size of the softener and the capacity of the resin.[1]
**Pressure:** As flow increases, friction through a softener rises and so does the pressure drop. Our main guide answers pressure questions at Water Softeners Buying Guide: What to Check Before You Buy[9]
The NSF/ANSI 44 standard requires that a water softener's pressure drop must not exceed 15 psi at the manufacturer's rated service flow, which must be at least four gpm.[9]
**Approved products:** Most plumbing products used in or around buildings must be evaluated and certified to WaterMark product specifications under the Plumbing Code of Australia. WaterMark certification is the process that authorises products for plumbing installations. A separate WaterMark technical specification sets minimum requirements for water treatment components used on domestic drinking water supply.[10],[11]
**Installation:** Both kinds of equipment connect to your plumbing, so backflow protection and approved fittings matter. Backflow is water flowing the wrong way, back into the supply. Check current requirements with your state or territory plumbing regulator and your water utility, and use a licensed plumber.
- The WaterMark water treatment specification says water treatment components at a system's first point of entry must include a non-testable backflow prevention device that meets AS/NZS 2845.1.[11]
- The same specification calls for warning labels stating that a certified dual check valve must be fitted on installation. It also requires installation instructions that refer to AS/NZS 3500.1.[11]
- Individual protection means fitting a backflow device where the water pipes connect to a fixture or appliance.[12]
- In Victoria, the Victorian Building and Plumbing Commission says plumbing work commenced on or after 20 October 2025 must comply with the 2025 version of the standard. Its summary of the installation clause says a backflow protection device must be installed as specified in Section 4.[13]
- Barwon Water's policy requires a testable backflow device at or near the boundary of medium or high hazard properties, with no connections bypassing it. That is one Victorian utility's rule, so ask your own water authority what applies.[12]
- The WaterMark specification states that it does not override the approvals processes of any jurisdiction.[11]
Which to choose
- Hard water is the problem: a softener is the tool built for it, because it swaps calcium and magnesium for non-hardness ions.[1]
- Taste or smell is the problem: look at activated carbon, which is used to control taste and odour compounds.[2]
- Nitrates, pesticides, algal toxins or other trace organic chemicals are the concern: carbon treatment is named for these contaminants.[2]
- You want fewer disinfection by-products: carbon placed before disinfection is the approach described for reducing their formation.[2]
- Both hardness and taste are issues: plan for two separate treatment steps, each with its own running needs and installation requirements.
Common questions
Do you need a filter with a water softener?
They do separate jobs. A softener exchanges hardness ions. Activated carbon is used in water treatment for contaminants such as nitrates, pesticides and disinfection by-products, and for taste and odour compounds.[1],[2]
What is the downside of a water softener?
A softener needs salt and uses about 50 gallons of water per regeneration. Softening also adds sodium to the water, at about 8 mg/L for each grain per gallon of hardness. Salt use depends on household size, water use, softener capacity and hardness.[1]
Sources
- [1]Unl (checked 2026-11-12)
- [2]Carbon, granulated activated (checked 2026-11-25)
- [3]NSF/ANSI 44 Technical Requirements (checked 2026-11-12)
- [4]Chlorine (checked 2026-11-11)
- [5]Hardness (as calcium carbonate) (checked 2026-11-25)
- [6]Sodium (checked 2026-11-11)
- [7]How Water Softeners Work: From Regeneration to Brine Walls (checked 2026-11-25)
- [8]Ion Exchange Softening (checked 2026-11-25)
- [9]Water Softener Pressure Drop Measurement – WC&P Online (checked 2026-11-25)
- [10]WaterMark product specifications (checked 2026-11-25)
- [11]WMTS-103:2016 Water treatment systems (other than (checked 2026-11-25)
- [12]OFFICIAL OFFICIAL Backflow Prevention and Containment Policy Guidelines (checked 2026-11-11)
- [13]Updated plumbing and drainage standards - Part 1: Water services (checked 2026-11-12)
How this guide was made
Drafted with AI assistance from the sources listed, then fact-checked and edited by the PouchMe team. PouchMe researches products from published information; we have not tested them ourselves.
How we research